Flexible, Double insulated single conductor
Aplicação:
PVC single-conductor cable suitable for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms, and in open air (fixed installation).Must not be installed directly in the ground or water.This two-approvals single-conductor cable is preferred for use in export-oriented mechanical engineering, in machine tools, production lines and systems engineering.
Cabo Construção
- Bare copper conductor, fine wire stranded
- 1st Insulation: special PVC, color black
- 2nd Insulation: special PVC
- Jacket color black
Faixa de temperatura: flexing -5°C to +90°C; fixed installation -40°C to +90°C
Tensão nominal: acc. to VDE U0/U 600/1000 V; acc. to UL 1000 V
A.C. teste de tensão, 50 Hz:4000 V
Vergamento raio mínimo: for flexible installation; approx. 7,5x cable Ø; for fixed installation; approx. 3x cable Ø
Propriedades
PVC self-extinguishing and flame retardant according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1
(equivalent DIN VDE 0472 part 804 test method B)
Condutores x cross-sec. mm² |
Diâmetro exterior |
Cobre peso
kg/km |
Peso
ca. kg/km |
AWG |
1x1.5 |
4.5 |
14.4 |
30.0 |
16 |
1x2.5 |
5.0 |
24.0 |
49.0 |
14 |
1x4 |
6.1 |
38.4 |
75.0 |
12 |
1x6 |
7.2 |
57.6 |
118.0 |
10 |
1x10 |
9.0 |
96.0 |
180.0 |
8 |
1x16 |
10.2 |
154.0 |
250.0 |
6 |
1x25 |
11.6 |
240.0 |
370.0 |
4 |
1x35 |
13.0 |
336.0 |
490.0 |
2 |
1x50 |
16.0 |
480.0 |
665.0 |
1 |
1x70 |
17.1 |
672.0 |
910.0 |
2/0 |
1x95 |
19.5 |
912.0 |
1195.0 |
3/0 |
1x120 |
22.3 |
1152.0 |
1545.0 |
4/0 |
|